APT
AUTONOMOUS PATIENT TRANSPORT

BATTERY SPECS
kWh Capacity: 4.2 kWh
Amp Hours: 94 Ah
Operating DC Voltage Range: 36 V-50.4 V
Cell Configuration: 12S 2P

WARNING: Do NOT exceed max charging voltage.
INVERTER SPECS
AC Output Voltage: 110V (*10%) |
Max DC Charge Current: 60A
Continues Surge Power: 3 kW Output Frequency: 50Hz/60Hz ($0.5Hz)
Waveform: Pure-Sine Wave Efficiency: 95%
DIMENSIONS
Weight: 175 lbs. (79.38 kg)
Width: 21.75 in (552.5 mm)
Depth: 27.56 in (700mm) + 6.5 in (165mm)
Height: 19.69 in (500 mm)
APT MINI
AUTONOMOUS PATIENT TRANSPORT
PARAMETERS
Note: Bulk, Absorption, Float, and Equalize are not applicable to lithium batteries but are included here with the correct numbers to input into your charge controller as they are our most commonly requested parameters.
Charge Voltage: 50.4V
Bulk Voltage:Pre-Programed (Not Applicable to Lithium Batteries)
Absorption Voltage: Pre-Programed (Not Applicable to Lithium Batteries) Absorption Time: 0 Minutes (Not Applicable to Lithium Batteries)
Float Voltage: Pre-Programed (Not Applicable to Lithium Batteries)
Fire Extinguishers: Yes
Low Voltage Cutoff: 36V
High Voltage Cutoff: 50.4V
Suggested Inverter Low Voltage Setting: Pre-Programed
Fan Noise: 28-42 dbA
FAQ'S
How do I connect this battery into my existing system?
Our product is designed with three GFCI outlets providing 120V AC.
How many can I put this battery in parallel/series?
This battery is not series capable but can be connected in parallel up to eight. Make sure that the total amount of these batteries in your configuration never exceeds eight total batteries. When connecting batteries in parallel, make sure all batteries are within 1 volt of one another.
Can I connect into this battery’s BMS to get extra info?
Our BMS protects the cells from overcharging, over-discharge, and
overcurrent.
What is the warranty on the battery?
We offer a comprehensive 10 year warranty on all of our batteries.